Self-Regulating Heating Cable KSR™
Self-Regulating Heating Cable KSR are an integral part of Thermon’s SnoTrace™ snow and ice melting systems. Designed and approved specifically for direct burial, KSR withstands the harsh conditions encountered during concrete placement.
The self-regulating heat output of KSR varies in response to the surrounding concrete temperatures.
When the concrete is at or below freezing temperatures, KSR will deliver the maximum power
output. As the concrete warms up, the power output will decrease. Energy efficiency can be accomplished without special or sophisticated controls.
EASY TO DESIGN
Determining the circuit layout of KSR for a snow and ice melting system is easy. The step-by-step design guide leads the reader through determining the heating requirements, selecting the trace heater spacing and establishing the number of heating circuits and accessories required to complete the SnoTrace system (for more information, refer to the SnoTrace KSR Design Guide, Form CPD1057).
With cut-to-length parallel circuitry, KSR easily adapts to variations in design found at the job site.
This can reduce or eliminate the need to redesign circuits off-site without details or sufficient time to
react.
EASY TO INSTALL
The demanding environment associated with forms, reinforcing steel and concrete placement requires that the trace heater be rugged. The fluoropolymer jacketed KSR with an additional silicone rubber outer jacket provides the needed durability. Yet it is flexible enough to adapt to steps, curved walkways, landings or other confined areas.
Installing and terminating KSR is easy. Simply unreel the amount of trace heater needed for the area/circuit and terminate with Thermon circuit fabrication kits and accessories. Power connection, splice kits, end termination and expansion joint kits are all designed specifically for the demanding application.
RATINGS
Power Output………………………………………………………………………………. 90 W/m (27 W/ft) @ 0 °C (32 °F)
concrete surface temperature
Minimum bend radius…………………………………..32 mm (1.25″)
Supply voltage…………………………………………………….208-277 Vac
Circuit protection………………………………………………………………………..
30 mA ground-fault protection required
CHARACTERISTICS
- 1.3 mm2
(16 AWG) Nickel-Plated Copper Bus Wire - Semiconductive Heating Matrix and
Fluoropolymer Dielectric Insulation - Tinned Copper Metallic Braid
- Silicone Rubber Outer Jacket
Datasheet: Self-Regulating Heating Cable KSR™